Open Phase Fault Detection of a Five-Phase Permanent Magnet Assisted Synchronous Reluctance Motor Based on Symmetrical Components Theory

Arafat, A., Choi, S., & Baek, J. (2017). Open Phase Fault Detection of a Five-Phase Permanent Magnet Assisted Synchronous Reluctance Motor Based on Symmetrical Components Theory. IEEE Transaction on Industrial Electronics. 64, 6465-6474.

Abstract

This paper presents a novel approach for open-phase fault detection of a five-phase permanent magnet assisted synchronous reluctance motor (PMa-SynRM). Under faults, the five-phase PMa-SynRM is expected to run at fault-tolerant control (FTC) mode, otherwise it draws a large amount of current with a significant reduction in the reluctance torque. To successfully achieve FTC operation of five-phase PMa-SynRM, the accurate detection of a fault condition has to be preceded. With the best of these authors knowledge, the detection of faults has been limitedly studied for five-phase motors. The analysis of open-phase fault in five-phase machine involves complicated conditions including single-phase open fault, two-phase adjacent fault, and two-phase nonadjacent fault. To perform the timely fault-tolerant operation, those faults have to be accurately analyzed and detected. In this paper, a novel symmetrical components (SCs) analysis is utilized to extract the feature of those fault conditions. This analysis will provide the types of faults by logically analyzing the pattern of magnitude and phase angle changes of the fundamental signal in the SCs. The proposed method has been comprehensively analyzed through theoretical derivation, finite-element simulations, and experimental testing through a 5 hp PMa-SynRM controlled by TI-DSP F28335.